What's included

What's included within an Annual Oil Fired Boiler Service

Preliminary visual inspection for visible water or oil leaks, low system pressure, oil smells and ask homeowner if experiencing any problems e.g. intermittent lock-outs, poor hot water performance or system pressure loss

Strip and clean heat exchanger(s), clean combustion chamber

Check Combustion chamber access door, insulation board and seals

Check and clean baffles

Clean burner combustion head, check electrodes and photocell

Replace nozzle and flexible fuel lines, date tag replacement flexible oil lines

Check flue system is intact, clean and unobstructed and flue terminal guard

Check combustion ventilation air supply

Check and replace burner seal if required

Check fuel flow, clean and replace fuel filters as necessary

Clean condensate discharge trap and check condensate discharge system

Check operation of Pressure Relief Valve

Check and re-pressurise expansion vessel as necessary

Inspect oil supply system

Check fire safety valve is fitted and check operation

Check for earth bonding to incoming oil line and fuse rating to boiler

Inspect oil tank, check for contamination, condition and support/base

Re-assemble and set up for clean and correct combustion to manufacturers specification

Check burner safety lock out function and appliance safety controls

Check boiler timer and controls

Clean magnetic system filter and set system pressure

Check boiler for correct operation of domestic hot water and central heating functions

Check for and test carbon monoxide alarm

Produce completed oil fired heating service report with combustion printout